DSpace Repository

Radyoterapı̇ Odasının Farklı Noktalarında Nötron Kirliliğinin Ölçülmesi

Show simple item record

dc.creator KARAMAN, Onur
dc.creator TANIR, PH.D., Ayşe Güneş
dc.date 2020-05-31T00:00:00Z
dc.date.accessioned 2020-07-27T10:21:48Z
dc.date.available 2020-07-27T10:21:48Z
dc.identifier https://dergipark.org.tr/tr/pub/sdufeffd/issue/54573/664357
dc.identifier 10.29233/sdufeffd.664357
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/50891
dc.description Radyoterapi, kanser tedavisinde kullanılan en önemli tedavi yöntemlerinden birisidir. Ancak, radyoterapide yüksek enerjili foton ve elektron demetlerinin kullanımı sırasında (>7 MV) lineer hızlandırıcı kafasında bulunan ağır metallerden kaynaklı nötron kirliliği oluşmaktadır. Bu durum, hedef hacimde ve çevresindeki diğer organlarda nötron kirliliğinden kaynaklı doz belirsizliğine neden olmakta ve ikincil kanser riski oluşturmaktadır. Bu çalışmada, 18 MV foton enerjisinde, Elekta Synergy lineer hızlandırıcıda Thermo Scientific Rad Eye NL marka nötron dedektörü ile alan açıklığının ve eşmerkeze olan uzaklığın nötron doz hızına olan etkisi incelenmiştir. Ayrıca, alan açıklığının nötron doz hızı üzerindeki etkisi eşmerkezde, eşmerkezden farklı uzaklıklarda, radyoterapi odası kapısının içi ve dışında, konsol odasında ölçümler alınarak araştırılmıştır. Radyoterapide, 18 MV enerjili fotonların neden olduğu nötron kirliliğinden kaynaklı doz belirsizliğinin ikincil kanser riskini artırabileceği öngörülmüştür. Bu nedenle, radyoterapide istenmeyen fotonötron dozunun dikkate alınmasının çok önemli olduğu sonucuna varılmıştır.
dc.description Radiotherapy is one of the most important treatment methods used in cancer treatment.. However, during the cancer treatment, the undesired photo-neutron caused by using high energy photon beams (> 7 MV) increases the secondary cancer risk. This causes dose uncertainty due to the neutron contamination in the target volume and other organs around it, and brings out a risk of secondary cancer. In this study, the effect of the square field size and the distance from the isocenter on the neutron dose rate was investigated by using Thermo Scientific RadEye neutron detector in 18 MV photon energy, Elekta Synergy linear accelerator. Moreover, the effect of the field size on the neutron dose rate was investigated at the isocenter, and at a different distance from the isocenter as well as at the inside and the outside of the radiotherapy room door, and the console room. In radiotherapy, dose uncertainty due to neutron contamination caused by photons with 18 MV energy is predicted to increase the risk of secondary cancer. It is concluded that it is crucial to take into consideration of the unwanted photo-neutron dose in the radiation treatment.
dc.format application/pdf
dc.language tr
dc.publisher Süleyman Demirel University
dc.publisher Süleyman Demirel Üniversitesi
dc.relation https://dergipark.org.tr/tr/download/article-file/1124227
dc.source Volume: 15, Issue: 1 36-44 en-US
dc.source 1306-7575
dc.source Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi
dc.subject Nötron kontaminasyonu,Medikal lineer hızlandırıcı,Nötron dedektör
dc.subject Neutron contamination,Medical linear accelerator,Neutron detector
dc.title Radyoterapı̇ Odasının Farklı Noktalarında Nötron Kirliliğinin Ölçülmesi tr-TR
dc.title Measurement of Neutron Contamination at Different Points in the Radiotherapy Room en-US
dc.type info:eu-repo/semantics/article