DSpace Repository

Evaluation of DNA Damage in Lymphocytes in Percutaneous Thoracic Mass Biopsies Performed with Computed Tomography

Show simple item record

dc.creator GUNDUZ, DEMET
dc.creator SAYGIN, Mustafa
dc.creator Aslankoç, Rahime
dc.creator AYYILDIZ, VEYSEL ATİLLA
dc.date 2023-08-15T00:00:00Z
dc.date.accessioned 2025-02-25T10:31:52Z
dc.date.available 2025-02-25T10:31:52Z
dc.identifier 70518957-3bf0-476b-986d-6147627edcf6
dc.identifier 10.22312/sdusbed.1287546
dc.identifier https://avesis.sdu.edu.tr/publication/details/70518957-3bf0-476b-986d-6147627edcf6/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/100121
dc.description Purpose: The increase in the medical and industrial uses of radiation in the last century has caused people to be exposed to higher doses of radiation. Although the harms of high-dose radiation on human health are known, the effects of low-dose radiation on health have not yet been fully elucidated. In this study, we aimed to investigate DNA damage in lymphocytes in patients with lung, pleura/thoracic wall masses planned for percutaneous thoracic mass biopsy with computed tomography (CT). Methods: Sixteen patients referred to the Radiology Clinic of a public institution hospital with lung, pleura/thoracic wall masses and scheduled to undergo a CT-guided percutaneous biopsy were included in the study. All the biopsies were performed with a 128-slice CT device (Definition AS, Siemens Medical Solutions, Forchheim, Germany). Lymphocytes were analyzed using the comet assay in the venous blood samples taken from the patients before and after the biopsy procedure. DNA damage was quantitatively evaluated with the imaging analysis method. Results: In the CT analysis data of the study group, the mean scan distance was found to be 19.92±3.60 sec, the mean total milliampere-seconds was 807.43±304.51, and the mean dose-length product was 765.44±278.36 mGy.cm. The mean comet score was 200.50±40.54 for the cells that migrated before the procedure and 237.37±27.85 for those migrating after the procedure. The post-procedure comet scores significantly increased compared to the pre-procedure comet scores (p=0.038). Conclusion: Post-procedure DNA damage was detected in patients who underwent CT-guided percutaneous biopsy.
dc.language eng
dc.rights info:eu-repo/semantics/openAccess
dc.title Evaluation of DNA Damage in Lymphocytes in Percutaneous Thoracic Mass Biopsies Performed with Computed Tomography
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account