DSpace Repository

The test-retest reliability and minimal detectable change of the six-minute walk test, timed up and go test, and 30-second chair stand test in people with epilepsy

Show simple item record

dc.creator Aktar, Burçin
dc.creator Baklan, Baris
dc.creator ÖZTURA, İBRAHİM
dc.creator BALCI, BİRGÜL
dc.date 2024-01-01T00:00:00Z
dc.date.accessioned 2025-02-25T10:38:24Z
dc.date.available 2025-02-25T10:38:24Z
dc.identifier cb00a190-9dbc-4c64-b434-8495f739fdf2
dc.identifier 10.1080/09593985.2023.2237566
dc.identifier https://avesis.sdu.edu.tr/publication/details/cb00a190-9dbc-4c64-b434-8495f739fdf2/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/101376
dc.description Background: The available evidence suggests that people with epilepsy have reduced cardio-respiratory fitness and muscle strength endurance, and impaired balance and mobility. The 6-minute walk test (6MWT), Timed Up and Go (TUG), and 30-second chair stand test (30CST) are physical performance tests frequently used in clinical practice. Objective: To establish the test-retest reliability and minimal detectable change of the 6MWT, TUG, and 30CST in people with epilepsy. Methods: The study was designed as an observational study. Forty-one people with epilepsy (23 females, 18 males; mean age 34.7 ± 10.4 years) participated. The 6MWT, TUG, and 30CST were tested by a trained physiotherapist during two sessions, which were conducted 7–14 days apart. The test-retest reliability of measures was assessed using the intra-class correlation coefficients (ICC) using two-way random effects and absolute agreement methods. The 95% limits of agreement, standard error of measurement (SEM), and minimal detectable change (MDC₉₅) were calculated. Results: The 6MWT (ICC = 0.92, SEM = 15.8, MDC₉₅ = 43.8), TUG (ICC = 0.95, SEM = 3.2, MDC₉₅ = 0.5) and 30CST (ICC = 0.92, SEM = 1.0, MDC₉₅ = 2.8) performance measurements demonstrated excellent test-retest reliability. The 95% limits of agreement was calculated, as illustrated in a Bland-Altman plot. Conclusion: The 6MWT, TUG, and 30CST are reliable for measuring physical performance. The findings of this study can support researchers and clinicians to decide if a change score of a person with epilepsy is likely to be measurement error or true change.
dc.language eng
dc.rights info:eu-repo/semantics/closedAccess
dc.title The test-retest reliability and minimal detectable change of the six-minute walk test, timed up and go test, and 30-second chair stand test in people with epilepsy
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account