DSpace Repository

Meskenlerdeki elektrik tesisatlarından kaynaklanan yangınların incelenmesi ve yangın risk analizlerinin yapılması = Investigation of fire caused by electrical installation in building and carrying out fire risk analysis /

Show simple item record

dc.creator Şengöz, Mehmet Cem, 1969- author 9343
dc.creator Merdan, Mustafa, 1949- thesis advisor 9126
dc.creator Süleyman Demirel Üniversitesi. Fen Bilimleri Enstitüsü. Elektronik ve Haberleşme Mühendisliği Anabilim Dalı. 9124 issuing body
dc.date 2011.
dc.identifier http://tez.sdu.edu.tr/Tezler/TF01727.pdf
dc.description In this thesis study, reports of fire in 01 October 2005- 30 November 2010 that are taken from Head of department of Antalya Metropolitan municipality converted into to assessable data. Then these data evaluated by using Microsoft Office 2003 Home Editition Excel. Based on the obtained results, it was determined that maximum fires occur in the region coded as number two. In this region, two district identified randomly an then at the building of district, construction connection lines of district, rising main installations of district , electrical devices used inside of building of district, and electrical installations of residential of district, analyses of risk of fire were made. While this analysis was made, suitability to regulations of .Electrical Interior Facilities Regulation. published by TMMOB Chamber of Electrical Engineers and principles about the measure, details and application areas of energy room published by General Directorate of TEDAS were gotten as reference. At the light of studies made on data, it is determined that at the dwellin in this two district chosen randomly, construction connection lines and rising main installations did not fit with determined standard. It was concluded that electrical installation in the dwelling and element of protection made a fuss consistently because installation projects did not compute according to using of air conditioner, water heater and electrical heater before 2004. Keywords: Fire, Fire Coused By Electric, Analysis of Risk.
dc.description Tez (Yüksek Lisans)- Süleyman Demirel Üniversitesi, Fen Bilimleri Enstitüsü, Elektronik Haberleşme Mühendisliği Anabilim Dalı, 2011.
dc.description Kaynakça var.
dc.description In this thesis study, reports of fire in 01 October 2005- 30 November 2010 that are taken from Head of department of Antalya Metropolitan municipality converted into to assessable data. Then these data evaluated by using Microsoft Office 2003 Home Editition Excel. Based on the obtained results, it was determined that maximum fires occur in the region coded as number two. In this region, two district identified randomly an then at the building of district, construction connection lines of district, rising main installations of district , electrical devices used inside of building of district, and electrical installations of residential of district, analyses of risk of fire were made. While this analysis was made, suitability to regulations of .Electrical Interior Facilities Regulation. published by TMMOB Chamber of Electrical Engineers and principles about the measure, details and application areas of energy room published by General Directorate of TEDAS were gotten as reference. At the light of studies made on data, it is determined that at the dwellin in this two district chosen randomly, construction connection lines and rising main installations did not fit with determined standard. It was concluded that electrical installation in the dwelling and element of protection made a fuss consistently because installation projects did not compute according to using of air conditioner, water heater and electrical heater before 2004. Keywords: Fire, Fire Coused By Electric, Analysis of Risk.
dc.language tur
dc.publisher Isparta : SDÜ Fen Bilimleri Enstitüsü,
dc.subject Süleyman Demirel Üniversitesi
dc.title Meskenlerdeki elektrik tesisatlarından kaynaklanan yangınların incelenmesi ve yangın risk analizlerinin yapılması = Investigation of fire caused by electrical installation in building and carrying out fire risk analysis /
dc.type text