DSpace Repository

İki kademeli CO2 transkritik çevrimli bir ısı pompası sisteminin termodinamik analizi = Thermodynamic analysis of a heat pump system with two-stage CO2 transcritical cycle /

Show simple item record

dc.creator Yüce, Müfit, 1989- author 159592
dc.creator Özgür, Arif Emre, 1977- thesis advisor 10046
dc.creator Süleyman Demirel Üniversitesi. Fen Bilimleri Enstitüsü. Enerji Sistemleri Mühendisliği Anabilim Dalı. 24663 issuing body
dc.date 2016.
dc.identifier http://tez.sdu.edu.tr/Tezler/TF03523.pdf
dc.description Refrigerants used in cooling systems for many years but due to understanding that CFC and HCFC gases ozone depleting these gases prohibited by the Montreal Protocol. Concerns with ODP (ozone depletion potential) and GWP (global warming potential) began to result in restrictions on the use of CFCs and HFCs and these gases have led to interest in other chemical refrigerants that can be used as alternative refrigerants, one of which is carbon dioxide (CO2). When alternative refrigerants start using in refrigeration and heat pump systems CO2 preferred due to it’s thermophsical and thermodynamic properties for provide a number of possibilities. Some possibilities about that CO2 is non-toxic and non-flammable, which provides the selection of installing systems where you want. CO2 has been using refrigeration industry from the growth stage. Nevertheless, around the critical point or above the critical point thermal throw caused decline the cooling effect and due to high operating pressures halocarbon refrigerants has left its place. Because of halocarbon refrigerants adverse effects on the environment, alternative natural refrigerant CO2 re started to be used as a refrigerant. In this study, by studying a heat pump system’s performance analized. Syystem’s parameter’s calculated with the help of Engineering Solver (EES) programme. Keywords: R-744, Transcritical Cycle, Heat Pump System
dc.description Tez (Yüksek Lisans) - Süleyman Demirel Üniversitesi, Fen Bilimleri Enstitüsü, Enerji Sistemleri Mühendisliği Anabilim Dalı, 2016.
dc.description Kaynakça var.
dc.description Refrigerants used in cooling systems for many years but due to understanding that CFC and HCFC gases ozone depleting these gases prohibited by the Montreal Protocol. Concerns with ODP (ozone depletion potential) and GWP (global warming potential) began to result in restrictions on the use of CFCs and HFCs and these gases have led to interest in other chemical refrigerants that can be used as alternative refrigerants, one of which is carbon dioxide (CO2). When alternative refrigerants start using in refrigeration and heat pump systems CO2 preferred due to it’s thermophsical and thermodynamic properties for provide a number of possibilities. Some possibilities about that CO2 is non-toxic and non-flammable, which provides the selection of installing systems where you want. CO2 has been using refrigeration industry from the growth stage. Nevertheless, around the critical point or above the critical point thermal throw caused decline the cooling effect and due to high operating pressures halocarbon refrigerants has left its place. Because of halocarbon refrigerants adverse effects on the environment, alternative natural refrigerant CO2 re started to be used as a refrigerant. In this study, by studying a heat pump system’s performance analized. Syystem’s parameter’s calculated with the help of Engineering Solver (EES) programme. Keywords: R-744, Transcritical Cycle, Heat Pump System
dc.language tur
dc.publisher Isparta : Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü,
dc.subject Süleyman Demirel Üniversitesi
dc.title İki kademeli CO2 transkritik çevrimli bir ısı pompası sisteminin termodinamik analizi = Thermodynamic analysis of a heat pump system with two-stage CO2 transcritical cycle /
dc.type text