DSpace Repository

LiF:MgCuNaSi Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonun Monte Carlo Yöntemiyle İncelenmesi

Show simple item record

dc.creator AYDIN, Bünyamin
dc.creator KUMRU, Mehmet N.
dc.creator YEĞİN, Gültekin
dc.creator AYDIN, M. Mustafa
dc.date 2014-12-31T00:00:00Z
dc.date.accessioned 2019-07-09T11:48:18Z
dc.date.available 2019-07-09T11:48:18Z
dc.identifier http://dergipark.org.tr/sdufeffd/issue/11280/134811
dc.identifier
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/45631
dc.description Many of the Thermoluminescence (TL) dosimeters are used in different areas in order to measure “personnel dose equivalent”. It’s analyzes must be done by determining different dosimetric characteristics and specialty of TL the material. Obtaining data which supplies energy dependence of the detector response function for TL supplies is very difficult when experimental methods are used and can be measured with a large error value. It’s possible to get the detailed information when these detectors are modeled at computers. In this study, LiF materials which are used as “TLD” doped with Mg, Cu, Na, and Si activators are modeled. TL dosimeter detector response function of the energy dependence has been found by the method of the MCNP Monte Carlo simulation method. In previous studies with the results obtained have been compared with the values obtained in this study
dc.description Özet: Birçok Termolüminesanas (TL) dozimetreleri “personel doz eşdeğerini” ölçmek için farklı alanlarda kullanılmaktadır. TL malzemelerin değişik dozimetrik özelliklerinin ve karakteristiklerinin belirlenerek analizlerinin yapılması gerekmektedir. TL malzemeleri için dedektör cevap fonksiyonlarının enerjiye bağlılığını veren verileri elde etmek, deneysel yöntemler kullanıldığında oldukça güçtür ve büyük hata değerleriyle birlikte ölçülebilmektedir. Bu dedektörler, bilgisayar ortamında modellendiğinde ayrıntılı bilgi almak mümkün olabilmektedir. Bu çalışmada, Mg, Cu, Na ve Si ile katkılanmış TLD olarak kullanılan LiF malzemeleri modellenmiştir. TL dozimetrelerin dedektör cevap fonksiyonlarının enerjiye bağlılığı MCNP Monte Carlo simülasyon yöntemi ile bulunmuştur. Önceden yapılmış çalışmalardan elde edilen sonuçlar ile bu çalışmada elde edilen değerler karşılaştırılmıştır.Anahtar kelimeler: LiF, Monte Carlo, TL, fotonThe Investigation of The Detector Response Function of The LiF:MgCuNaSi Thermoluminescence Detector Against The Photons In Different Energies By Using Monte Carlo MethodAbstract: Many of the Thermoluminescence (TL) dosimeters are used in different areas in order to measure “personnel dose equivalent”. It's analyzes must be done by determining different dosimetric characteristics and specialty of TL the material. Obtaining data which supplies energy dependence of the detector response function for TL supplies is very difficult when experimental methods are used and can be measured with a large error value. It's possible to get the detailed information when these detectors are modeled at computers. In this study, LiF materials which are used as “TLD” doped with Mg, Cu, Na, and Si activators are modeled. TL dosimeter detector response function of the energy dependence has been found by the method of the MCNP Monte Carlo simulation method. In previous studies with the results obtained have been compared with the values obtained in this study.Key words: LiF, Monte Carlo, TL, photon
dc.format application/pdf
dc.language tr
dc.publisher Süleyman Demirel University
dc.publisher Süleyman Demirel Üniversitesi
dc.relation http://dergipark.org.tr/download/article-file/116421
dc.source Volume: 9, Issue: 2 177-185 en-US
dc.source 1306-7575
dc.subject LiF, Monte Carlo, TL, photon
dc.subject LiF, Monte Carlo, TL, foton
dc.title LiF:MgCuNaSi Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonun Monte Carlo Yöntemiyle İncelenmesi en-US
dc.title LiF:MgCuNaSi Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonun Monte Carlo Yöntemiyle İncelenmesi en-US
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account