dc.description Nükleer tıbbınamaçlarından biri hedef organlardaki anormal metabolik aktivitelerin tanısıdır.Rutin bir nükleer tıp görüntüleme sürecinde, radyofarmasötik kullanılır.Radyofarmasötiğin radyonüklid kısmı gama radyasyonu yayar. Bu radyasyon GamaKamera veya Tek Foton Emisyon Bilgisayarlı Tomografi (SPECT) tarafından dedekteedilir. Anatomik görüntüleri birleştirmek için SPECT cihazına BilgisayarlıTomografi (BT) cihazı eklenmiştir (SPECT – BT) . Bu cihazın görüntü kalitesidoğru tanı ve hastalıkların tedavisi için önemlidir. Kalite konteol testlerisayesinde, cihazdaki performans değişiklikleri belirlenir. Homojenite,sensivite, rezolüsyon, linearite gibi çeşitli kalite kontrol parameterelerigama kameralar ve SPECT için geliştirilmiştir. Kalite kontrol testi sonuçlarıkabul edilebilir sonuçlarla karşılaştırılarak doğrulanmalıdır. Bu çalışmada,SPECT-CT'nin kalite kontrol testleri National Electrical ManufacturersAssociation (NEMA) tarafından önerildiği gibi yapılmış ve bazı düzeltme yöntemlerininaraştırılması amaçlanmıştır.
dc.description The one of the aim ofnuclear medicine is diagnosis of an abnormal metabolic activities in targetorgans.  In a routine nuclear medicineimaging procedure, a radiopharmaceutical is used. Radiopharmaceutical’sradionuclide part emits gamma radiation. This radiation is dedected by GammaCamera or Single Photon Emission Computed Tomography (SPECT). A computedtomography (CT) device was added to the SPECT(SPECT- CT). To combine anatomicalimages. Image quality of this device is important for accurate diagnosis andtreatment of diseases. By means of quality control tests, performance changesof device are dedected. A various quality control parameters such asuniformity, sensivity, resolution, linearity have been developed for Gammacameras, SPECT. Quality control test results are should be verify by comparing acceptableresults. In this study, quality control tests of SPECT-CT are performed asproposed by the National Electrical Manufacturers Association ( NEMA) and it wasaimed to investigate some correction methods.
dc.format application/pdf
dc.language en
dc.publisher Süleyman Demirel University
dc.publisher Süleyman Demirel Üniversitesi
dc.relation http://dergipark.org.tr/download/article-file/721331
dc.source Volume: 14, Issue: 1 39-56 en-US
dc.source 1306-7575
dc.subject Gama kamera,SPECT,SPECT-BT,Kalite Kontrol Testleri
dc.subject Gamma camera,SPECT,SPECT – CT,Quality control tests
dc.title SPECT – BT ’nin Kalite Kontrolleri en-US
dc.title Quality Control Tests of SPECT- CT en-US