Inkudostapedial Bağlantı Süreksizliklerinin Onarımında Kullanılan Cam İyonomer Çimentosunun Biyomedikal Özellikleri

Show simple item record

dc.creator ÜNAL, Ahmet
dc.creator BEKEM, Aylin
dc.creator SERVER, Ela
dc.creator ALKAN, Zeynep
dc.creator YİĞİT, Özgür
dc.date 2015-01-04T19:35:58Z
dc.date.accessioned 2019-07-09T12:00:09Z
dc.date.available 2019-07-09T12:00:09Z
dc.identifier http://dergipark.org.tr/sdufenbed/issue/20805/222237
dc.identifier 10.19113/sdufbed.13296
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/46605
dc.description In this study, the biomechanical properties of glass ionomer cement used for repair of incudostapedial joint bridge in ear in two different distances was investigated. A master block was used to locate the incus and stapes with a 91 degree angle constant. Two experimental groups were composed according to the distances between incus and stapes which were adjusted as 1.0 and 2.0 mm. The mixture of bone cement was applied to the gap between incus and stapes and adhere them together. Compression tests were performed to these joints. Strength value of group 1 were found significantly higher than group 2 (p=0.042). The fragility of bone cement used in 2 mm gap was 25,5% higher compared to 1 mm gap
dc.description In this study, the biomechanical properties of glass ionomer cementused for repair of incudostapedial joint bridge in ear in two different distances wasinvestigated. A master block was used to locate the incus and stapes with a 91degree angle constant. Two experimental groups were composed according to thedistances between incus and stapes which were adjusted as 1.0 and 2.0 mm. Themixture of bone cement was applied to the gap between incus and stapes andadhere them together. Compression tests were performed to these joints. Strengthvalue of group 1 were found significantly higher than group 2 (p=0.042). Thefragility of bone cement used in 2 mm gap was 25,5% higher compared to 1 mmgap.
dc.format application/pdf
dc.language en
dc.publisher Süleyman Demirel University
dc.publisher Süleyman Demirel Üniversitesi
dc.relation http://dergipark.org.tr/download/article-file/194030
dc.source Volume: 18, Issue: 3 152-156 en-US
dc.source 1308-6529
dc.subject Glass ionomer cement Incus Stapes Compression Fragility
dc.title Inkudostapedial Bağlantı Süreksizliklerinin Onarımında Kullanılan Cam İyonomer Çimentosunun Biyomedikal Özellikleri en-US
dc.type info:eu-repo/semantics/article