DSpace Repository

Demir ve Alüminyumun Doğal Sularda UV Spektrofotometrik Tayini İçin Yöntem Geliştirilmesi ve Elde Edilen Verilerin Kemometrik Kalibrasyon Yöntemleriyle Değerlendirilmesi

Show simple item record

dc.creator AKTAŞ, A. Hakan
dc.creator MUTLUTÜRK, Bengisu
dc.date 2015-01-07T08:35:38Z
dc.date.accessioned 2019-07-09T12:00:36Z
dc.date.available 2019-07-09T12:00:36Z
dc.identifier http://dergipark.org.tr/sdufenbed/issue/20805/222244
dc.identifier 10.19113/sdufbed.26626
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/46830
dc.description Bu çalışmada, kemometrik kalibrasyon yöntemlerinden temel bileşen analizi yöntemi (PCA), temel bileşen regresyonu yöntemi (PCR) ve kısmi en küçük kareler yöntemi (PLS), doğal sularda bulunan Fe³â º ve Al³â º'ün miktar tayininde başarı ile uygulanmıştır. UV- Görünür Alan Spektroskopisinden elde edilen veriler kemometrik olarak değerlendirilmiştir. Uygulamada iki farklı ligand chrome azurol S (CAS) ve pyrocatechol violet (PCV) denenmiş ve daha kararlı sonuçlar elde edildiğinden CAS ile çalışmalara devam edilmiştir. Fe³â º ve Al³â º CAS ile komplekslerinin spektrofotometrik yöntemlerle uygun parametreleri belirlenmiş (ligand miktarı, pH, bekleme süreleri, metal derişimi ve absorbans arasındaki ilişki ve yabancı iyon etkisi) ve optimum koşullar sağlanmıştır. Optimum koşullar sağlandıktan sonra Fe³â º ve Al³â º içeren doğal su örneğinin spektrofotometrik tayinleri gerçekleştirilmiş ve elde edilen veriler kemometrik olarak değerlendirilmiştir.
dc.description In this study, principal component analysis method (PCA), principal component regression method (PCR), partial least squares method (PLS) of chemometry calibration methods, are successfully realized on quantitation of Fe³⁺ and Al³⁺ present at natural water. The data gathered from UV- Visible Spectroscopy are evaluated chemometrically. In the application two distinctive ligand chrome azurol S (CAS) and pyrocatechol violet (PCV) are tested and studies are proceeded with CAS due to more stable results that are obtained. Optimum parameters (ligand amount, pH, waiting period, relation between metal concentration and absorbance, foreign ion effect) and conditions of Fe³⁺ and Al³⁺ CAS and their complexes are determined with spectrophotometric methods. After the optimum conditions are provided, spectrophotometric determinations of natural water including Fe³⁺ and Al³⁺ are realized and obtained data are evaluated as chemometry
dc.format application/pdf
dc.language en
dc.publisher Süleyman Demirel University
dc.publisher Süleyman Demirel Üniversitesi
dc.relation http://dergipark.org.tr/download/article-file/194036
dc.source Volume: 18, Issue: 3 52-59 en-US
dc.source 1308-6529
dc.subject PCA PCR PLS UV-Görünür Alan Spektroskopisi Kemometri CAS PCV
dc.subject PCA PCR PLS UV-Visible Spectrophotometer Chemometry CAS PCV
dc.title Demir ve Alüminyumun Doğal Sularda UV Spektrofotometrik Tayini İçin Yöntem Geliştirilmesi ve Elde Edilen Verilerin Kemometrik Kalibrasyon Yöntemleriyle Değerlendirilmesi en-US
dc.type info:eu-repo/semantics/article