DSpace Repository

A Rare Anatomical Form Of Quadricuspid Aortic Valve Diagnosed By Transthoracic Echocardiography

Show simple item record

dc.creator Baş, Hasan
dc.creator İçli, Atilla
dc.creator Doğan, Abdullah
dc.creator Aksoy, Fatih
dc.date 2014-07-25T19:38:39Z
dc.date.accessioned 2019-07-09T12:09:18Z
dc.date.available 2019-07-09T12:09:18Z
dc.identifier http://dergipark.org.tr/sdutfd/issue/21017/225937
dc.identifier 10.17343/sdutfd.80058
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/47774
dc.description Dear Editor, Quadricuspid aortic valve (QAV) is a rare congenital anomaly, far less common than bicuspid or unicuspid aortic valves. In a series of autopsies it ocurred in about 0.008% and 0,033% of cases (1). The first case was reported by Balington (2) in 1862. Since then only a few cases (3, 4) have been reported. Most of the cases are discovered incidentally at the time of aortography, aortic valve replacement surgery, or autopsy. A 22- year man was examined for symptoms of atypical angina in emergency service. He had no previous history of cardiovascular disease or drug use. Physical examination is normal. His blood pressure was 120/60 mmHg and pulse rate was 86 beats/min. On auscultation of the heart, there was a grade 1-2/4 diastolic murmur in aortic area. The electrocardiogram showed normal sinus rhythm and the chest radiogram was normal. Transthoracic echocardiography showed a QAV with three equal size cusps and one smaller cusp in the short-axis view (Fig. A). The left ventricular size and ejection fraction were normal and an eccentric mild aortic regurgitation in the long axis view (Fig. B). Our case is type B according to classification of QAV by Hurwitz and Roberts in 1973 (5). Sometimes diagnosis may be missed with trans-thoracic echocardiography and transesophageal approach is needed. Especially in young patients with aortic regurgitation, when the number of valve leaflets is not properly identified by TTE, a transesophageal echocardiogram should be performed. Management of patients with QAV is represented by strict follow-up, because those patients may require aortic valve replacement in their future life. QAV diagnosis before aortic valve replacement is important to guide surgical technique, being often associated to anomalous positioning of coronary ostia (6). There have been reports of endocarditis in patients with QAV, and patients with unequal cusps are considered at higher risk for this complication
dc.description Quadricuspid aortic valve (QAV) is a rare congenital anomaly, far less common than bicuspid or unicuspid aortic valves.A 22-year man was examined for symptoms of atypical angina in emergency service. He had no previous history of cardiovascular disease or drug use.Transthoracic echocardiography showed a QAV with three equal size cusps and one smaller cusp in the short-axis view.Management of patients with QAV is represented by strict follow-up, because those patients may require aortic valve replacement in later life.There have been reports of endocarditis in patients with QAV, and patients with unequal cusps are considered at higher risk for this complication.
dc.format application/pdf
dc.language en
dc.publisher Süleyman Demirel University
dc.publisher Süleyman Demirel Üniversitesi
dc.relation http://dergipark.org.tr/download/article-file/196927
dc.relation http://dergipark.org.tr/download/article-file/250294
dc.relation http://dergipark.org.tr/download/article-file/250295
dc.source Volume: 21, Issue: 2 en-US
dc.source 1300-7416
dc.source 2602-2109
dc.subject Quadricuspid aortic valve, Transthoracic Echocardiography
dc.title A Rare Anatomical Form Of Quadricuspid Aortic Valve Diagnosed By Transthoracic Echocardiography en-US
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account