| dc.creator |
Şahin, Volkan; KIRIKKALE ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, KLİNİK BİLİMLER BÖLÜMÜ, PROTETİK DİŞ TEDAVİSİ ANABİLİM DALI |
|
| dc.creator |
Jodati, Hossein; ODTÜ, Biyomedikal Mühendislik Bölümü |
|
| dc.creator |
Evis, Zafer; ODTÜ, Mühendislik Bilimleri Bölümü |
|
| dc.date |
2018-12-06T00:00:00Z |
|
| dc.date.accessioned |
2019-07-09T12:11:55Z |
|
| dc.date.available |
2019-07-09T12:11:55Z |
|
| dc.identifier |
http://dergipark.org.tr/sdusbed/issue/40837/326886 |
|
| dc.identifier |
10.22312/sdusbed.326886 |
|
| dc.identifier.uri |
http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/48019 |
|
| dc.description |
Amaç:Bu in-vitro çalışmanın amacı; uzatılmış saklama sürelerinin, uzatılmış modelelde etme süresine sahip irreversible hidrokolloid ölçü malzemelerinin yırtılmadayanımı üzerine etkisini incelemektir. Materyal-Metod: Beşticari (BluePrintXcreme, Hydrogum 5, Kromopan, Alginmaxve Alginelle) ve bir özel formüleedilmiş uzatılmış model etme süresinesahip irreversible hidrokolloid ölçü malzemesi kullanılarak ISO 21563:2013standartlarına uyumlu seksen dört adet numune hazırlanmıştır. Her bir ölçü malzemesine sait numuneler rastgele iki gruba ayrılmış (n=7) ve hemen veya 120 saatlik saklama süresi sonunda yırtılma testine tabitutulmuşlardır. Yırtılma dayanımı değerleri N/mm cinsinden ifade edilmiş veveriler iki yönlü varyans analizi testi(irreversible hidrokolloid markası, saklama süresi) kullanılarak analizedilmiştir. Çoklu karşılaştırmalara, Tukey testi kullanılarak yapılmıştır (p=0.05).Bulgular: Uzatılmış model etme süresine sahip irreversiblehidrokolloid ölçü malzemelerinin yırtılma dayanımları, irreversiblehidrokolloid markası parametresi (p<0.0001) ve irreversiblehidrokolloid markası-saklama süresi etkileşimi tarafından etkilenmiştir (p=0.005). tarafından etkilenmiştir Saklama süresi, uzatılmış model etme süresinesahip irreversible hidrokolloid ölçü malzemelerinin yırtılma dayanımlarını, 120saat saklama süresi sonunda yırtılma dayanımı artan Alginmax ölçü malzemesi haricinde etkilememiştir (p<0.05). Hemen yapılan yırtılma dayanımı testinde BlueprintXcreme en yüksek ortalama yırtılma dayanımı değerlerine sahipken (1.08±0.19 N/mm) Alginelle en düşük ortalama yırtılma dayanımı değerlerini göstermiştir (0.51±0.3 N/mm). 120saat saklama süresi sonunda Hydrogum 5 en yüksek ortalama yırtılma dayanımıdeğerlerine sahipken (1.15± 0.12 N/mm) Alginelle en düşük ortalama yırtılma dayanımı değerlerinigöstermiştir (0.55±0.04 N/mm). Sonuç: Test edilen uzatılmışmodel elde etme süresine sahip ticari irreversiblehidrokolloid ölçü malzemelerinin tümü,yırtılma dayanımlarını 120 saatlik saklama süresi sonunda korumuştur. |
|
| dc.description |
Objective:The aim of this in vitro study was to evaluate the effect of prolonged storagetimes on the tear strength of extended-pour irreversible hydrocolloidimpression materials. Material and Method: Eighty four specimens were fabricated from five commercial extended-pour irreversiblehydrocolloid impression materials (BluePrint Xcreme, Hydrogum 5, Kromopan, Alginmax and Alginelle) as well as one experimental formula inaccordance with the ISO 21563:2013 standard effective for irreversible hydrocolloid impression materials. Specimenswere randomly divided in two groups for each impression material (n=7) andsubjected to tear strength test immediately (base line) or after 120 hours ofstorage. Tear strength values were obtainedin N/mm and data were analysed withtwo-way ANOVA (irreversible hydrocolloid brand, storage time). Multiplecomparisons were performed with Tukey’s test (p=0.05). Results:The tear strength of the extended-pourirreversible hydrocolloid impression materials were affected by brand (p<0.0001)and brand-storage time interaction (p=0.005). Storage time did not influencethe tear strengths of the extended-pour irreversible hydrocolloid impressionmaterials tested except Alginmax whose mean tear strengths increased after 120hours of storage (p<0.05). At baseline measurements Blueprint Xcreme provided the highest mean tear strengthvalues (1.08±0.19 N/mm) whereas Alginelle provided the lowest mean tear strength values(0.51±0.3 N/mm). Hydrogum 5 provided the highest tear strength values after 120hours of storage (1.15± 0.12 N/mm)whereas Alginelle provided the lowestmean tear strength values (0.55±0.04 N/mm). Conclusion.All commercialextended-pour irreversible hydrocolloid impression materials tested maintainedtheir tear strengths after 120 hours of storage. |
|
| dc.format |
application/pdf |
|
| dc.language |
en |
|
| dc.publisher |
Süleyman Demirel University |
|
| dc.publisher |
Süleyman Demirel Üniversitesi |
|
| dc.relation |
http://dergipark.org.tr/download/article-file/589596 |
|
| dc.source |
Volume: 9, Issue: 3
26-30 |
en-US |
| dc.source |
2146-1937 |
|
| dc.source |
2146-247X |
|
| dc.subject |
Tear Strength,Irreversible Hydrocolloid,Impression Material |
|
| dc.subject |
Tear strength,irreversible hydrocolloid,impression material |
|
| dc.title |
Effect of Storage Time on Tear Strength of Extended-Pour Irreversible Hydrocolloid Impression Materials |
en-US |
| dc.title |
Effect of storage time on tear strength of extended-pour irreversible hydrocolloid impression materials |
en-US |
| dc.type |
info:eu-repo/semantics/article |
|