dc.creator Şahin, Volkan; KIRIKKALE ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, KLİNİK BİLİMLER BÖLÜMÜ, PROTETİK DİŞ TEDAVİSİ ANABİLİM DALI
dc.creator Jodati, Hossein; ODTÜ, Biyomedikal Mühendislik Bölümü
dc.creator Evis, Zafer; ODTÜ, Mühendislik Bilimleri Bölümü
dc.date 2018-12-06T00:00:00Z
dc.date.accessioned 2019-07-09T12:11:55Z
dc.date.available 2019-07-09T12:11:55Z
dc.identifier http://dergipark.org.tr/sdusbed/issue/40837/326886
dc.identifier 10.22312/sdusbed.326886
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/48019
dc.description Amaç:Bu in-vitro çalışmanın amacı; uzatılmış saklama sürelerinin, uzatılmış modelelde etme süresine sahip irreversible hidrokolloid ölçü malzemelerinin yırtılmadayanımı üzerine etkisini incelemektir. Materyal-Metod:  Beşticari  (BluePrintXcreme, Hydrogum 5,  Kromopan, Alginmaxve Alginelle) ve bir özel formüleedilmiş  uzatılmış model etme süresinesahip irreversible hidrokolloid ölçü malzemesi kullanılarak ISO 21563:2013standartlarına uyumlu seksen dört adet numune hazırlanmıştır.  Her bir ölçü malzemesine sait numuneler  rastgele iki gruba ayrılmış (n=7) ve  hemen veya 120 saatlik saklama süresi sonunda yırtılma testine tabitutulmuşlardır. Yırtılma dayanımı değerleri N/mm cinsinden ifade edilmiş veveriler  iki yönlü varyans analizi testi(irreversible hidrokolloid markası, saklama süresi) kullanılarak analizedilmiştir. Çoklu karşılaştırmalara, Tukey testi kullanılarak yapılmıştır (p=0.05).Bulgular: Uzatılmış model etme süresine sahip irreversiblehidrokolloid ölçü malzemelerinin yırtılma dayanımları, irreversiblehidrokolloid markası parametresi (p<0.0001)  ve irreversiblehidrokolloid markası-saklama süresi etkileşimi tarafından etkilenmiştir (p=0.005).   tarafından etkilenmiştir  Saklama süresi, uzatılmış model etme süresinesahip irreversible hidrokolloid ölçü malzemelerinin yırtılma dayanımlarını, 120saat saklama süresi sonunda yırtılma dayanımı artan   Alginmax  ölçü malzemesi haricinde etkilememiştir (p<0.05).  Hemen yapılan yırtılma dayanımı testinde BlueprintXcreme en yüksek ortalama yırtılma dayanımı değerlerine sahipken  (1.08±0.19 N/mm) Alginelle  en düşük ortalama yırtılma dayanımı değerlerini göstermiştir (0.51±0.3 N/mm). 120saat saklama süresi sonunda Hydrogum 5 en yüksek ortalama yırtılma dayanımıdeğerlerine sahipken (1.15± 0.12 N/mm) Alginelle en düşük  ortalama yırtılma dayanımı değerlerinigöstermiştir (0.55±0.04 N/mm). Sonuç: Test edilen   uzatılmışmodel elde etme süresine sahip  ticari irreversiblehidrokolloid ölçü malzemelerinin tümü,yırtılma dayanımlarını 120 saatlik saklama süresi sonunda korumuştur.  
dc.description Objective:The aim of this in vitro study was to evaluate the effect of prolonged storagetimes on the tear strength of extended-pour irreversible hydrocolloidimpression materials. Material and Method: Eighty four specimens were fabricated from  five commercial extended-pour irreversiblehydrocolloid impression materials (BluePrint Xcreme, Hydrogum 5,  Kromopan, Alginmax and Alginelle)  as well as one experimental formula inaccordance with the ISO 21563:2013 standard  effective for irreversible hydrocolloid impression materials. Specimenswere randomly divided in two groups for each impression material (n=7) andsubjected to tear strength test immediately (base line) or after 120 hours ofstorage.  Tear strength values were obtainedin N/mm and data were   analysed withtwo-way ANOVA (irreversible hydrocolloid brand, storage time). Multiplecomparisons were performed with Tukey’s test (p=0.05). Results:The tear strength of the extended-pourirreversible hydrocolloid impression materials were affected by brand (p<0.0001)and brand-storage time interaction (p=0.005). Storage time did not influencethe tear strengths of the extended-pour irreversible hydrocolloid impressionmaterials tested except Alginmax whose mean tear strengths increased after 120hours of storage (p<0.05).  At baseline measurements Blueprint Xcreme provided the highest mean tear strengthvalues (1.08±0.19 N/mm) whereas Alginelle provided  the lowest mean tear strength values(0.51±0.3 N/mm). Hydrogum 5 provided the highest tear strength values after 120hours of storage  (1.15± 0.12 N/mm)whereas Alginelle provided  the lowestmean tear strength values (0.55±0.04 N/mm). Conclusion.All commercialextended-pour irreversible hydrocolloid impression materials tested maintainedtheir tear strengths after 120 hours of storage. 
dc.format application/pdf
dc.language en
dc.publisher Süleyman Demirel University
dc.publisher Süleyman Demirel Üniversitesi
dc.relation http://dergipark.org.tr/download/article-file/589596
dc.source Volume: 9, Issue: 3 26-30 en-US
dc.source 2146-1937
dc.source 2146-247X
dc.subject Tear Strength,Irreversible Hydrocolloid,Impression Material
dc.subject Tear strength,irreversible hydrocolloid,impression material
dc.title Effect of Storage Time on Tear Strength of Extended-Pour Irreversible Hydrocolloid Impression Materials en-US
dc.title Effect of storage time on tear strength of extended-pour irreversible hydrocolloid impression materials en-US
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account