| dc.creator |
Ulu, Murat; İZMİR KATİP ÇELEBİ ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ |
|
| dc.creator |
Akçay, Hüseyin; İZMİR KATİP ÇELEBİ ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ |
|
| dc.date |
2019-03-21T00:00:00Z |
|
| dc.date.accessioned |
2019-07-09T12:12:08Z |
|
| dc.date.available |
2019-07-09T12:12:08Z |
|
| dc.identifier |
http://dergipark.org.tr/sdusbed/issue/44044/518842 |
|
| dc.identifier |
10.22312/sdusbed.518842 |
|
| dc.identifier.uri |
http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/48132 |
|
| dc.description |
Amaç: Gömülüdişlerin çekimi çene cerrahisi alanında en sık yapılan işlemlerden biridir veişlem sonrası trismus, ağrı ve ödem meydana gelebilmektedir. Bu çalışmada gömülüüçüncü molar dişlerin çekimi sonrasında oluşan ödemin değerlendirilmesinde 3boyutlu ölçüm yöntemi ile konvansiyonel yöntemlerden biri olan esnek cetvelleyapılan pletismografik ölçüm yönteminin kıyaslanarak değerlendirilmesi amaçlanmıştır.Materyal ve metot: Çalışmayaalt çenesinde bilateral, gömülü diş çekimi endikasyonu koyulmuş 18 yaş veüzerinde 60 hasta dahil edildi. Hastalar iki farklı gruba ayrıldı, çekimsonrası hastaların yüzünün bir tarafına kinesio bant yapıştırılırken (KB grubu,n:60) ; karşıt tarafta yapılan dişçekimi sonrası hastalara herhangi bir uygulama yapılmadı (kontrol grubu, n:60).Ameliyattan hemen önce (T0), sonrası 2.(T1) ve 7.(T2) günlerde ödem ölçümleri3dMD ve pletismografik yöntemlerle ayrı ayrı gerçekleştirildi.Bulgular: Eldeedilen sonuçlara göre; T0-T1; T0-T2 zaman aralığında meydana gelen ödemin değerlendirilmesinde3dMD ölçüm yötemi ile pletismografik ölçüm yöntemi arasında istatistikselolarak anlamlı bir korelasyon tespit edilmemişir (p>0,05).Sonuç: Maksillofasiyalbölgede yapılan cerrahi müdahalelerden sonra yumuşak dokuda meydana gelenhacimsel değişikliklerin değerlendirilmesinde, dokuya doğrudan temas etmeden ölçümyapılabilmesine olanak tanıdığı için 3D tarama sistemlerinin daha güvenilirsonuçlar verdiği düşünülmektedir. |
|
| dc.description |
Objective: The extraction of impacted teeth is oneof the most common procedures in the field of oral surgery, and trismus, pain,and edema may occur after the procedure. The aim of this study was to compare thethree dimensional facial screening system and plethysmographic technique in themeasurement of edema after third molar teeth extraction.Material and method: Sixty patients aged 18 years and olderwere included in the study with indication of bilateral, impacted toothextraction in the lower jaw. The patients were divided into two differentgroups, a group with the kinesio tape (KT) was adhered on one side of the faceafter extraction (KT group, n: 60); no application after the tooth extractionon the opposite side (control group, n: 60). Immediately before the operation(T0), after the 2nd (T1) and 7 (T2) days, edema measurements were performedseparately by 3DMD and plethysmographic methods.Results: According to the results, there was nostatistically significant correlation between 3dMD measurement method andpletismographic measurement method in the evaluation of T0-T1, T0-T2 time intervaledema (p> 0.05).Conclusion: In the evaluation of thevolumetric changes in the soft tissue after surgical interventions in themaxillofacial region, it is thought that 3D scanning systems give more reliableresults because it allows measurement without direct contact with the tissue. |
|
| dc.format |
application/pdf |
|
| dc.language |
tr |
|
| dc.publisher |
Süleyman Demirel University |
|
| dc.publisher |
Süleyman Demirel Üniversitesi |
|
| dc.relation |
http://dergipark.org.tr/download/article-file/673902 |
|
| dc.source |
Volume: 10, Issue: 1
48-52 |
en-US |
| dc.source |
2146-1937 |
|
| dc.source |
2146-247X |
|
| dc.subject |
gömülü diş,ödem,kinezioloji,üç boyutlu görüntüleme |
|
| dc.subject |
impacted teeth,edema,kinesiology,three-dimensional image |
|
| dc.title |
Ödemin Değerlendirilmesinde Yüz Tarama Sistemi ile Pletismografik Ölçüm Yönteminin Karşılaştırılması |
en-US |
| dc.title |
Comparison of facial scanning system and plethysmographic technique in measurement of edema |
en-US |
| dc.type |
info:eu-repo/semantics/article |
|