dc.description Buçalışmada, Aliağa Gaz Türbinleri ve Kombine Çevrim Santraline termodinamiğin І.ve ІІ. yasası aracılığıyla, enerji ve ekserji analizi uygulanmıştır. Santralinakış şemasına bağlı olarak her bir ünitenin giriş ve çıkış noktalarıbelirlenmiştir. Belirlenen noktaların termodinamik özellikleri (Sıcaklık,basınç ve kütlesel debi) santralden anlık olarak alınmıştır. Alınan buözellikler ile her bir noktanın entalpileri, entropileri ve ekserjileri sayısalolarak EES (Engineering Equation Solver) paket programı yardımıylahesaplanmıştır.  Yapılanhesaplamalar sonunda santralin I. ve II. yasa verimleri sırasıyla % 32.8 ve %43.4 olarak belirlenmiştir. Sonuç olarak; her bir üniteye enerji ve ekserjianalizleri uygulanarak santralde en fazla ekserji kaybının sırasıyla yanmaodası, ısı kazanı, yoğuşturucu, ünitelerinde olduğu, diğer ünitelerde iseekserji kaybının düşük bir şekilde meydana geldiği belirlenmiştir. Santraldekiekserji kayıplarının azaltılması ile verimde artışın sağlanacağı öngörülmektedir. Verim artışına paralel olarak enerji maliyetleri azalacak veçevreye salınan zararlı emisyonlarda düşüş meydana gelecektir.
dc.description In this study, by using the first andsecond law of thermodynamics the energy and exergy analyses have been appliedto the Aliaga Gas turbines and combined power plant cycle. Depending on thepower plant flow charts diagram the input and output points for each uniteshave been determined. The thermodynamic properties (e.g., temperature, pressureand mass flow rate) of the specified points momentarily were collected from thepower plant cycle. By using these properties, the enthalpy, entropy and exergyquantity were calculated for each point in Engineering Equation Solver (EES)programs. The results of the study show that the efficienciesfor the first and second laws of thermodynamics are found as 32.8 % and 43.4 %respectively. As a result; when the energy and exergy analyses were applied foreach unit of the power plant, the maximum exergy destruction was in turn-combustionchamber, boiler, condenser; and the exergy destruction in other units was foundto be very low. When reducing the exergy destruction in the power plant, itsefficiency is expected to increase. The increased efficiency is parallel with energycost decreased, and thus it will be occured the decline in harmful emissions releasedto the environment.
dc.format application/pdf
dc.publisher Süleyman Demirel University
dc.publisher Süleyman Demirel Üniversitesi
dc.relation http://dergipark.org.tr/download/article-file/385951
dc.source Volume: 5, Issue: 3 537-545 en-US
dc.source 1308-6693
dc.subject Ekserji,Isıl verim,, Güç santrali,Kombine çevrim
dc.subject Combined power plant,Natural gas,Case study,Thermodynamic performance,Exergy analysis
dc.title BİR KOMBİNE ÇEVRİM SANTRALİNİN EKSERJİ ANALİZİ en-US
dc.title EXERGY ANALYSIS OF A COMBINED CYCLE POWER PLANT en-US
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account