dc.description The hip dysplasia is described by an irregular relation between the femoral head and the acetabulum. Insufficient coverage of the femoral head by the acetabulum leads the development of dysplasia in the incongruity hip joint. Several osteotomies are carried out for treatment by changing with coverage angle of the femoral head in the hip joint. In this paper, the effects of osteotomy techniques used in the surgery applications on the coverage angle are investigated experimentally. Salter osteotomy technique was applied on a patient-specific artificial hip models manufactured at different osteotomy angles. The contact pressure distribution and area were measured by using Fuji Film Prescale sensor in the hip joint. The results were compared with each other. The average contact pressure expectedly decreases as long as osteotomy coverage angle increases but, the contact area decreases unexpectedly
dc.description The hip dysplasia is described by an irregular relation between the femoral head and the acetabulum. Insufficient coverage of the femoral head by the acetabulum leads the development of dysplasia in the incongruity hip joint. Several osteotomies are carried out for treatment by changing with coverage angle of the femoral head in the hip joint. In this paper, the effects of osteotomy techniques used in the surgery applications on the coverage angle are investigated experimentally. Salter osteotomy technique was applied on a patient-specific artificial hip models manufactured at different osteotomy angles. The contact pressure distribution and area were measured by using Fuji Film Prescale sensor in the hip joint. The results were compared with each other. The average contact pressure expectedly decreases as long as osteotomy coverage angle increases but, the contact area decreases unexpectedly.
dc.format application/pdf
dc.language en
dc.publisher Süleyman Demirel University
dc.publisher Süleyman Demirel Üniversitesi
dc.relation http://dergipark.org.tr/download/article-file/195406
dc.source Volume: 2, Issue: 3 243-247 en-US
dc.source 1308-6693
dc.title EFFECTS OF SALTER PELVIC OSTEOTOMY ANGLE ON CONTACT AREA AND PRESSURE DISTRIBUTION IN THE HIP JOINT: AN EXPERIMENTAL STUDY en-US
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account