| dc.description |
Bu çalışmada günlük hayatta maruziyetinden sakınılamayanfarklı frekanslardaki cihazların oluşturduğu elektromanyetik yayılım için kaseşdeğer modelleri oluşturulmuştur. Günümüzde elektromanyetik alan yayancihazların kullanımının giderek yaygınlaşması maruz kalınan frekans ve güçseviyelerinin çeşitliliğini artırmaktadır. Elektromanyetik dalgalar farklıgüçlerde ve farklı frekanslarda, insan vücudunda değişik etkilerdebulunmaktadır. Bu etkiler vücutta dokuları ısıtmakta veya kimyasal yoldandeğişimlere yol açmaktadır. Buçalışmada, 900 MHz ve 1800 MHz frekanslarındakicep telefonu, 2.45 GHz frekansındaki kablosuz haberleşme cihazlarının ve ayrıca27.12 MHz frekansındaki tıbbi fizyoterapi tedavi cihazlarının (kısa dalgadiatermi) insan kas dokusu üzerindeki etkilerini belirlemek amaçlı kas eşdeğersıvıları oluşturulmuştur. Bu oluşturulan fantom model üzerinde elektromanyetikmaruziyetin neden olduğu ısıl değişimler ölçülmüştür. |
|
| dc.description |
In this study, the muscle equivalent tissue models wereexamined for unavoidable electromagnetic radiation from various devices whichused in daily life. Nowadays, daily exposure growing because of the increasinguse of electromagnetic field-emitting devices and their widespread diversity ofthe frequency and power levels. Electromagnetic waves make different effects indifferent frequencies and different strengths human body. This effect causessome changes in body by heating or chemically. In this study, for differentfrequencies such as 900 and 1800 MHz frequencies for mobile phone and 2.45 GHzfrequency for wireless communication devices and also the 27.12 MHz frequencyfor medical devices, physiotherapy treatment (short-wave diathermy), muscleequivalent liquid models are aimed for determining their effects on humanmuscle tissue. Thermal changes in this phantom were measured for validation onthe model of electromagnetic exposure as well. |
|
| dc.format |
application/pdf |
|
| dc.language |
tr |
|
| dc.publisher |
Süleyman Demirel University |
|
| dc.publisher |
Süleyman Demirel Üniversitesi |
|
| dc.relation |
https://dergipark.org.tr/tr/download/article-file/804402 |
|
| dc.source |
Volume: 7, Issue: 3
498-504 |
en-US |
| dc.source |
1308-6693 |
|
| dc.subject |
Kas dokusu,Elektromanyetik alan,Fantom model |
|
| dc.subject |
Electromagnetic field,Muscle tissue,Phantom model |
|
| dc.title |
ELEKTROMANYETİK ALAN MARUZİYETİNİN KAS DOKUSUNDA OLUŞTURDUĞU ETKİNİN MODELLENMESİ VE ANALİZİ |
tr-TR |
| dc.title |
MODELING AND ANALYSIS OF THE EFFECT OF ELECTROMAGNETIC FIELD EXPOSURE ON THE MUSCLE TISSUE |
en-US |
| dc.type |
info:eu-repo/semantics/article |
|