DSpace Repository

Bilgisayarlı Tomografi Çekimlerinde Hastanın Yakın Çevresinde Radyasyon Dozu Ölçümleri

Show simple item record

dc.creator Günay, Osman; OKAN ÜNİVERSİTESİ
dc.creator Demir, Mustafa; İSTANBUL ÜNİVERSİTESİ - CERRAHPAŞA, CERRAHPAŞA TIP FAKÜLTESİ, DAHİLİ TIP BİLİMLERİ BÖLÜMÜ, NÜKLEER TIP ANABİLİM DALI
dc.date 2019-12-25T00:00:00Z
dc.date.accessioned 2020-01-02T08:34:20Z
dc.date.available 2020-01-02T08:34:20Z
dc.identifier https://dergipark.org.tr/tr/pub/sdufenbed/issue/49749/544773
dc.identifier 10.19113/sdufenbed.544773
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/49370
dc.description İyonizeradyasyonun en yoğun kullanıldığı görüntüleme yöntemlerinden biri bilgisayarlıtomografi (BT) dir. Bilgisayarlı tomografi çekimlerinde X-ışınları kullanılır.Çekim sırasında X-ışınlarının bir kısmı, radyasyon fiziği yasalarına görehastadan ve sistemden çevreye saçılır. Bu saçılan radyasyondan kaynaklanan radyasyondozunun belirlenmesi hasta, hastaya eşlik etme zorunda kalan hasta yakını ve sağlıkçalışanları açısından önemlidir. Bu çalışmanın amacı BT görüntülemesi sırasındahastadan ve ortamdaki çeşitli materyallerden çevreye yayılan radyasyondankaynaklanan dozunun belirlenmesidir. Bu çalışmada insan eşdeğeri olan AldersonRando fantomun göğüs ve baş-boyun BT görüntülemesi yapıldı. BT görüntülemesırasında fantomdan 10, 20, 30 ve 40 cm uzaklıklara termolüminisansdozimetreler (TLD) yerleştirilerek radyasyon dozu ölçümleri yapıldı TLDdozimetrelerin kalibrasyonları ve okumaları Çekmece Nükleer AraştırmalarMerkezinde yapıldı. Göğüs BT görüntülemede çevreye saçılan ortalama radyasyondozunun 6.75±1.07µSvile 21.68±1.45 µSv arasında değiştiği belirlendi. Baş-boyungörüntülemede ise çevreye saçılan ortalama radyasyon dozunun 8.38±0.81 µSv ile 26.57±0.98 µSvarasında değiştiği belirlendi. Çekim sırasında hastaya eşlik etmek zorundakalan şahısların doz maruziyetlerinin müsaade edilen limitlerin altında olduğu tespitedildi.
dc.description Ionizingradiation is intensively used in diagnostic medical imaging and Computedtomography (CT) is the most requested among the modalities. During exposure,X-rays are usually scattered from the patient and the system according to theradiation physics laws. Thus, estimation of the received dose caused by thescattered radiation is important for the patients, patients' companions and thehealthcare workers. The aim of this study was to determine the radiation dosefrom the patient’s body and various materials in the environment during CTimaging. In this study, chest and head and neck CT scans were performed onhuman tissue equivalent Alderson Rando phantom. During CT imaging, radiationdose measurements were achieved by thermoluminescent dosimeters (TLD) placed atdistances of 10, 20, 30 and 40 cm from the phantom. In chest CT imaging, themean radiation dose to the environment ranged from 6.75 ± 1.07 µSv to 21.68 ±1.45 µSv. While, Head and neck imaging led to radiation dose ranged from 8.38 ±0.81 µSv to 26.57 ± 0.98 µSv. The exposure danger of the accompanyingindividuals was found to be minimal and below the permissible limits.
dc.format application/pdf
dc.language tr
dc.publisher Süleyman Demirel University
dc.publisher Süleyman Demirel Üniversitesi
dc.relation https://dergipark.org.tr/tr/download/article-file/868382
dc.source Volume: 23, Issue: 3 792-796 en-US
dc.source 1308-6529
dc.subject BT,TLD,X ışınları,Radyasyon dozları
dc.subject CT,TLD,X-ray,Radiation doses
dc.title Bilgisayarlı Tomografi Çekimlerinde Hastanın Yakın Çevresinde Radyasyon Dozu Ölçümleri tr-TR
dc.title Radiation Dose Measurements around Patient in Computed Tomography Imaging en-US
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account