DSpace Repository

Biomimetic compliant lower limb exoskeleton (BioComEx) and its experimental evaluation

Show simple item record

dc.creator BAŞER, Özgür
dc.creator KILIÇ, Ergin
dc.creator KIZILHAN, Hasbi
dc.date 2019-04-30T21:00:00Z
dc.date.accessioned 2020-10-06T09:29:53Z
dc.date.available 2020-10-06T09:29:53Z
dc.identifier 1f24d7f4-feb1-4fbd-83f5-7014b7c3651d
dc.identifier 10.1007/s40430-019-1729-4
dc.identifier https://avesis.sdu.edu.tr/publication/details/1f24d7f4-feb1-4fbd-83f5-7014b7c3651d/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/54974
dc.description Exoskeleton robots are generally used for rehabilitation and load-carrying applications. Stable and flexible walking with minimal energy consumption of the human body is achieved by the compliant operation of the human joints. Essentially, the stiffness of the human ankle joint varies continuously, while the stiffness of the knee and hip joints remains nearly constant during loading phases of the walking cycles. With inspiration from the human leg biomechanics, a new biomimetic compliant lower limb exoskeleton robot (BioComEx) was constructed and its preliminary experimental tests were carried out in this paper. A variable stiffness actuator was developed for the ankle joint of BioComEx, and series elastic actuator designs were employed in the knee and hip joints of the robot. The joint actuators of BioComEx were designed longitudinally in order to be embedded inside of the thigh and shank leg segments for the compactness. Separate force sensors were employed in each segment of the robot for the modularity of the control strategies. Since the exoskeletons can be used for both load-carrying and rehabilitation, the developed robot was tested in both human-in-charge and robot-in-charge modes, respectively. The robot needs to mimic movement of healthy user joints in the human-in-charge mode and maximize the compliance between the user and robot; thus, the interaction forces should be reduced as possible. Hence, a modular closed-loop impedance control algorithm was developed for this mode. On the other hand, in the robot-in-charge mode, the robot joints need to track predefined gait references to make the patient walk. PID position control algorithm was chosen for preliminary test of the robot in this mode. Experimental results show that BioComEx is sufficiently satisfactory for walking applications of healthy and paralyzed users.
dc.language eng
dc.rights info:eu-repo/semantics/closedAccess
dc.title Biomimetic compliant lower limb exoskeleton (BioComEx) and its experimental evaluation
dc.type info:eu-repo/semantics/article