Diagnostics of calibration methods: model adequacy of UV-based determinations

Show simple item record

dc.creator ERZENGİN, Ömer Utku
dc.creator AKTAŞ, Ahmet Hakan
dc.date 2016-11-30T21:00:00Z
dc.date.accessioned 2020-10-06T10:47:18Z
dc.date.available 2020-10-06T10:47:18Z
dc.identifier 8661a79f-b7fc-4019-9197-d7693cbca63e
dc.identifier 10.1002/cem.2853
dc.identifier https://avesis.sdu.edu.tr/publication/details/8661a79f-b7fc-4019-9197-d7693cbca63e/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/65319
dc.description Models such as ordinary least squares, independent component analysis, principle component analysis, partial least squares, and artificial neural networks can be found in the calibration literature. Linear or nonlinear methods can be used to explain the structure of the same phenomenon. Each type of model has its own advantages with respect to the other. These methods are usually grouped taxonomically, but different models can sometimes be applied to the same data set. Taxonomically, ordinary least square and artificial neural network use completely different analytical procedures but are occasionally applied to the same data set. The aim of the study of methodological superiority is to compare the residuals of models because the model with the minimum error is preferred in real analyses. Calibration models, in general, are based on deterministic and stochastic parts; in other words, the data are equal to the model + the error. Explaining a model solely using statistics such as the coefficient of determination or its related significance values is sometimes inadequate. The errors of a model, also called its residuals, must have minimum variance compared to its alternatives. Additionally, the residuals must be unpredictable, uncorrelated, and symmetric. Under these conditions, the model can be considered adequate. In this study, calibration methods were applied to the raw materials, hydrochlorothiazide and amiloride hydrochloride, of a drug, as well as a sample of the drug tablet. The applied chemical procedure was fast, simple, and reproducible. The various linear and nonlinear calibration methods mentioned above were applied, and the adequacy of the calibration methods was compared according to their residuals.
dc.language eng
dc.rights info:eu-repo/semantics/closedAccess
dc.title Diagnostics of calibration methods: model adequacy of UV-based determinations
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account