dc.description In this study, effects of position, diameter (5, 6, 7, 8 mm) and angle (30 degrees-180 degrees) of a mobile plug, located at the hot outlet side in a Ranque-Hilsch Vortex Tube (RHVT), were determined experimentally for best performance. In addition to plug parameters, effects of supply pressure (200-420 kPa) and number of nozzles (2, 4, 6) were also studied. The internal diameter (D) of the vortex tube used in the experiments was 9 mm; the ratio of the length of the vortex tube to its diameter (L/D) was 15. Four different plug locations were studied. The maximum difference in the temperatures of hot and cold streams was obtained for the plug diameter of 5 mm, tip angles of 30 degrees and 60 degrees, 4 nozzles and by keeping the plug location at the far extreme end. (C) 2008 Elsevier Ltd and IIR. All rights reserved.
dc.description <p>In this study, effects of position, diameter (5, 6, 7, 8 mm) and angle (30&ndash;180) of a mobile<br />plug, located at the hot outlet side in a Ranque&ndash;Hilsch Vortex Tube (RHVT), were<br />determined experimentally for best performance. In addition to plug parameters, effects<br />of supply pressure (200&ndash;420 kPa) and number of nozzles (2, 4, 6) were also studied. The<br />internal diameter (D) of the vortex tube used in the experiments was 9 mm; the ratio of<br />the length of the vortex tube to its diameter (L/D) was 15. Four different plug locations<br />were studied. The maximum difference in the temperatures of hot and cold streams was<br />obtained for the plug diameter of 5 mm, tip angles of 30 and 60, 4 nozzles and by keeping<br />the plug location at the far extreme end</p>
dc.language eng
dc.rights info:eu-repo/semantics/closedAccess
dc.title Experimental investigation of the performance of a Ranque-Hilsch vortex tube with regard to a plug located at the hot outlet
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account