DSpace Repository

Optimization of Lead (II) Adsorption onto Cross-Linked Polycarboxylate-Based Adsorbent by Response Surface Methodology

Show simple item record

dc.creator TAŞDEMİR, Rukiye
dc.creator ERZENGİN, Sıddıka Gamze
dc.creator YİĞİTARSLAN, Sibel
dc.date 2020-09-30T21:00:00Z
dc.date.accessioned 2021-01-21T08:25:08Z
dc.date.available 2021-01-21T08:25:08Z
dc.identifier b026a7db-4ba1-467e-912b-7cada08a882a
dc.identifier 10.1007/s13369-020-05029-w
dc.identifier https://avesis.sdu.edu.tr/publication/details/b026a7db-4ba1-467e-912b-7cada08a882a/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/85978
dc.description Due to the harmful effects to environment and public health, lead has to be removed from wastewater. The novelty of this study is the investigation of the adsorption of lead by a cross-linked polycarboxylate-based adsorbent synthesized, the characterization of adsorbent with FTIR, SEM-EDS, XRD and the optimization of the effective parameters such as initial lead concentration, pH and temperature by response surface methodology. In here, Box-Behnken experimental design was applied by using ANOVA-supported Design Expert software. It was statistically confirmed that the surface representing the adsorption process conforms to the reduced cubic model. The common effects of the parameters were determined, and the equation was obtained to predict lead removal under the desired conditions. It was understood that both Langmuir and Freundlich isotherms can be used to describe the adsorption data. The negative free energy of adsorption process indicated the spontaneous reaction. The values of enthalpy and entropy were determined as - 12.57 kJ mol(-1)and - 0.036 kJ mol(-1)K(-1), respectively. Maximum lead removal reached to 79.7% at the initial concentration of 480.7 ppm, pH 8 and 25 degrees C. The selectivity of adsorbent in both lead- and cadmium-containing aqueous solution was also studied. Adsorption was found to be in favor of metal ions with higher initial concentration, and lead was adsorbed more by the effect of electronegativity when the concentration of two ions was equal. Desorption experiments of lead showed that the adsorption process was highly chemical and less physical, and only the physical part of it was desorbed.
dc.language eng
dc.rights info:eu-repo/semantics/closedAccess
dc.title Optimization of Lead (II) Adsorption onto Cross-Linked Polycarboxylate-Based Adsorbent by Response Surface Methodology
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account