Analysis of a Heat Exchanger Coil Tube in a Petrochemical Reactor After Fire

Show simple item record

dc.creator Karakas, Serdar
dc.date 2010-01-01T01:00:00Z
dc.date.accessioned 2021-12-03T11:19:27Z
dc.date.available 2021-12-03T11:19:27Z
dc.identifier 2be4284d-fb92-4735-a444-2e42e8991ad4
dc.identifier 10.1515/htmp.2010.29.4.233
dc.identifier https://avesis.sdu.edu.tr/publication/details/2be4284d-fb92-4735-a444-2e42e8991ad4/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/90620
dc.description The paper is focused on the estimation of the remaining service life of a centrifugally-cast stainless steel heat exchanger tube component which was exposed to high temperatures during a fire incident Detailed microstructural analyses and tensile tests were carried out to evaluate the metallurgical condition of the tube The microstructure of the exposed steel was compared to its as-cast counterparts Coarsened precipitates and secondary precipitation were observed at the grain boundaries The tensile properties of the specimen exposed to the fire were impaired and the steel was therefore not recommended for further use The coarsening of the grain boundary precipitates was caused mainly by short-term high-temperature exposure of the steels during the fire
dc.language eng
dc.rights info:eu-repo/semantics/closedAccess
dc.title Analysis of a Heat Exchanger Coil Tube in a Petrochemical Reactor After Fire
dc.type info:eu-repo/semantics/article