DSpace Repository

One-Year Clinical Evaluation of the Efficacy of a New Daytime At-Home Bleaching Technique

Show simple item record

dc.creator Aladag, Akin
dc.creator TÜRKÜN, MURAT
dc.creator Celik, Esra Uzer
dc.creator Gokay, Necmi
dc.date 2010-01-01T01:00:00Z
dc.date.accessioned 2021-12-03T11:20:59Z
dc.date.available 2021-12-03T11:20:59Z
dc.identifier 469fe2df-bbfb-4a7f-8355-781de4c98097
dc.identifier 10.1111/j.1708-8240.2010.00325.x
dc.identifier https://avesis.sdu.edu.tr/publication/details/469fe2df-bbfb-4a7f-8355-781de4c98097/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/91246
dc.description The aim of this study was to compare the clinical efficacy and side effects of a new daytime at-home bleaching technique (28% carbamide peroxide [CP] gel) with the overnight application of 10% CP and to determine the change of tooth color 1-year post-treatment. Twenty healthy volunteers were assigned to one of two sample groups of 10. All participants employed one of the two at-home bleaching systems: (1) the new daytime at-home bleaching system including 28% CP gel with a non-custom-fit tray (Meta Tray, Remedent, Deurle, Belgium) for 20 minutes, and (b) the conventional overnight at-home bleaching system with a 10% CP gel and a custom-fit tray (Opalescence PF, Ultradent, South Jordan, UT, USA) for 6 to 8 hours. Digital images and CIE (International Commission on Illumination) L*, a*, and b* spectrophotometric measurements were taken at baseline, after the bleaching treatment and 1-year post-treatment. Tooth and gingival sensitivity was measured with a specially designed 4-point scale. Significant differences were found in L*, a*, and b* values, between initial and post-treatment, for both bleaching systems (p < 0.05). However, no significant difference was detected between post-treatment and 1-year follow-up. The bleaching effectiveness of Opalescence PF was found to be superior to that of Meta Tray, considering the color parameter of Delta E (p < 0.05). Meta Tray provoked less tooth sensitivity (p < 0.05), however gingival sensitivity appeared more in this group (p < 0.05). Within the limitations of this study, it can be concluded that the new daytime at-home bleaching system tested (Meta Tray) produced significant bleaching effects. However, the clinical efficacy of the overnight bleaching system was found to be superior to the daytime at-home bleaching system evaluated in this study. The whitening effect remained similar 1-year after the bleaching treatment for both at-home bleaching systems.
dc.language eng
dc.rights info:eu-repo/semantics/closedAccess
dc.title One-Year Clinical Evaluation of the Efficacy of a New Daytime At-Home Bleaching Technique
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account