DSpace Repository

Calculation of gamma-ray attenuation properties of some antioxidants using Monte Carlo simulation method

Show simple item record

dc.creator Karahan, M.
dc.creator Tekin, H. O.
dc.creator Sayyed, M. I.
dc.creator Kilicoglu, O.
dc.creator Erguzel, T. T.
dc.creator Kara, U.
dc.creator Konuk, M.
dc.date 2018-09-01T00:00:00Z
dc.date.accessioned 2021-12-03T11:31:57Z
dc.date.available 2021-12-03T11:31:57Z
dc.identifier 8ceb0c24-d0e8-4161-885f-299c3956ee7c
dc.identifier 10.1088/2057-1976/aad297
dc.identifier https://avesis.sdu.edu.tr/publication/details/8ceb0c24-d0e8-4161-885f-299c3956ee7c/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/93257
dc.description Antioxidants can protect normal cells from reactive oxygen species as a protective agent. Therefore, it is important to know radiation attenuation properties of antioxidants. In the present study, nine different types of antioxidant samples were investigated using Monte Carlo simulation method. MCNPX general-purpose Monte Carlo code (version 2.6.0) was utilized to investigate the attenuation parameters of antioxidant samples such as Rosmarinic acid, Butylhydroxyanisole, Butylhydroxytoluene, Morin, Piperonyl butoxide, Ascorbyl Palmitate, Citric acid, Malic acid, and Nordihydroguaiaretic acid. The mass attenuation coefficients (mu/p) values have been calculated against photon energies of 0.122, 0.356, 0.511, 0.662, 1.173 and 1.33 MeV. From these values, the effective atomic number (Zell), mean free path (MFP) and half value layer (HVL) have been calculated and compared with XCOM data. The results obtained by the MCNPX Monte Carlo code were close to those of standard XCOM data. The obtained results showed that the attenuation of photons in antioxidant samples increased with decreasing energy. Z(eff) values for the selected antioxidants molecules varied between 3.75-4.787. It is also found that malic acid and citric acid have smaller HVL values comparing with rest of antioxidants examined. It can be concluded that, modeled and validated standard MCNPX geometry could be useful to the scientific community for similar future radiation-attenuation studies using different types of biological materials and biological systems.
dc.language eng
dc.rights info:eu-repo/semantics/closedAccess
dc.title Calculation of gamma-ray attenuation properties of some antioxidants using Monte Carlo simulation method
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account