DSpace Repository

Effect of Triton X-100 on the Electrochemical Behavior of Hydrophobic Lapatinib Used in the Treatment of Breast Cancer: A First Electroanalytical Study

Show simple item record

dc.creator Aksoz, Begum Evranos
dc.creator DOĞAN TOPAL, BURCU
dc.date 2021-07-01T00:00:00Z
dc.date.accessioned 2021-12-03T11:46:54Z
dc.date.available 2021-12-03T11:46:54Z
dc.identifier abde9f33-a230-418f-97d3-e7d0172ef509
dc.identifier 10.1149/1945-7111/ac0ec3
dc.identifier https://avesis.sdu.edu.tr/publication/details/abde9f33-a230-418f-97d3-e7d0172ef509/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/94124
dc.description A novel electroanalytical method has been developed for the quantification of hydrophobic lapatinib in the presence of non-ionic surfactant Triton X-100 on a glassy carbon electrode. Lapatinib presented three well-defined anodic peaks (Ep (1), Ep (2), and Ep (3)) by square wave voltammetry. The oxidation behavior of Ep (1) and Ep (2) showed diffusion-adsorption mix controlled processes by cyclic voltammetry. The possible electro-oxidation mechanism is discussed. The stripping conditions and square wave voltammetry parameters were optimized. The sensitivity of the proposed method was increased in the presence of Triton X-100. The hydrophobic interaction between Triton-X-100 and lapatinib guaranteed that more drug molecules could rapidly reach the electrode surface. The adsorptive stripping square wave voltammetry exhibits a linear calibration range from 2.0 x 10(-8) to 1.0 x 10(-6) mol l(-1) for both ip (1) and ip (2) in 0.1 M H2SO4. The developed method was applied for the quantification of lapatinib in serum sample and pharmaceutical dosage form with satisfactory accuracy and precision. In the serum sample, the values of LOD were found to be 5.71 x 10(-9) and 2.79 x 10(-9) mol l(-1) for ip (1) and ip (2), respectively. The developed method shows excellent analytical performance with nano-level detection limits, simplicity, and green chemistry compatibility.
dc.language eng
dc.rights info:eu-repo/semantics/closedAccess
dc.title Effect of Triton X-100 on the Electrochemical Behavior of Hydrophobic Lapatinib Used in the Treatment of Breast Cancer: A First Electroanalytical Study
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account