DSpace Repository

Comparative thermodynamic evaluation of a geothermal power plant by using the advanced exergy and artificial bee colony methods

Show simple item record

dc.creator Demircan, Cihan
dc.creator KEÇEBAŞ, ALİ
dc.creator ÖZKARACA, OSMAN
dc.date 2018-08-01T00:00:00Z
dc.date.accessioned 2021-12-03T11:54:32Z
dc.date.available 2021-12-03T11:54:32Z
dc.identifier beac692e-c470-4494-af61-aa4ecb54af57
dc.identifier 10.1016/j.energy.2018.05.095
dc.identifier https://avesis.sdu.edu.tr/publication/details/beac692e-c470-4494-af61-aa4ecb54af57/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/94624
dc.description In this study, the thermodynamic performance of a binary geothermal power plant (GPP) is comparatively evaluated using the exergy analysis and optimization method. Thus, in addition to routes to improve the thermodynamic performance of the system, the thermodynamic relationships between the system components and improvement performances of the components are determined. With this aim, the Sinem GPP located in Aydin province in Turkey as a real system is selected. All data from the system are collected and a numerical model simulating the real system is developed. On the developed model, the conventional and advanced exergy analyses for exergy analysis and the artificial bee colony (ABC) method for optimization process are performed. The results of the study show that total exergy efficiencies of the conventional exergy analysis, advanced exergy analysis and artificial bee colony are determined as 39.1%, 43.1% and 42.8%, respectively. The exergy efficiency obtained from advanced exergy analysis is higher compared to the other two methods. This is due to the fact that theoretical and unavoidable operation assumptions in advanced exergy analysis are arbitrary as a single value depending on the decision maker. However, decision variables in the ABC method are within certain constraints chosen by the decision maker. It is better to select constraint limits instead of an arbitrary single value selection. Therefore, its arbitrary values should be confirmed with any optimization method. Additionally, the highest exergy destruction identified in the three methods is occurred in heat exchangers as the condenser and vaporizer. (C) 2018 Elsevier Ltd. All rights reserved.
dc.language eng
dc.rights info:eu-repo/semantics/closedAccess
dc.title Comparative thermodynamic evaluation of a geothermal power plant by using the advanced exergy and artificial bee colony methods
dc.type info:eu-repo/semantics/article