DSpace Repository

Color Change after 25% Hydrogen Peroxide Bleaching with Photoactivation: A Methodological Assessment Using Spectrophotometer versus Digital Photographs

Show simple item record

dc.creator Husain, Nadin Al-Haj
dc.creator UĞURLU, Muhittin
dc.creator Ozcan, Mutlu
dc.date 2022-07-01T00:00:00Z
dc.date.accessioned 2023-01-09T12:03:42Z
dc.date.available 2023-01-09T12:03:42Z
dc.identifier 68fe597f-f2a4-4b5c-876b-8d5ebdb93702
dc.identifier 10.3390/ma15145045
dc.identifier https://avesis.sdu.edu.tr/publication/details/68fe597f-f2a4-4b5c-876b-8d5ebdb93702/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/97952
dc.description This study aimed to evaluate the color change of teeth bleached with light activation using two different objective color measurement approaches after two years of clinical follow-up. A cross-sectional retrospective clinical study according to STROBE was followed including 30 participants. The 25% hydrogen peroxide gel (Philips Zoom) was applied with a supplementary LED light for 15 min in four cycles. Tooth color was assessed based on CIEL*a*b* values using a spectrophotometer (Spectroshade) at different time points (baseline, post bleaching, 1 week, 1 year, and 2 years). Standardized digital photographs were taken at each time point. The L*, a*, and b* values were measured from the digital photographs using Adobe Photoshop software. The color difference (Delta E) was separately calculated using the L*, a*, and b* values obtained with spectrophotometric and photographic analyses at each evaluation time. Data were analyzed with non-parametric tests (p < 0.05). A color regression was detected by both measurement approaches after 1 and 2 years (p < 0.05). Greater Delta E values were acquired with the spectrophotometer compared to the digital photographic analysis (p < 0.05). Although a greater color change was observed with the spectrophotometer, both approaches were able to detect the color rebound using the 25% hydrogen peroxide light-activated in-office system. Digital photographic analysis might therefore be used to assess color change after bleaching.
dc.language eng
dc.rights info:eu-repo/semantics/openAccess
dc.title Color Change after 25% Hydrogen Peroxide Bleaching with Photoactivation: A Methodological Assessment Using Spectrophotometer versus Digital Photographs
dc.type info:eu-repo/semantics/article