THERMODYNAMIC ANALYSIS FOR INDUSTRIAL CABINET PROVIDING SIMULTANEOUS HEATING AND COOLING THAT CAN BE USED IN THE FOOD INDUSTRY

Show simple item record

dc.creator AKARSLAN KODALOĞLU, Feyza
dc.creator ÜÇGÜL, İbrahim
dc.creator ELBİR, Ahmet
dc.date 2022-01-01T00:00:00Z
dc.date.accessioned 2023-01-09T12:05:43Z
dc.date.available 2023-01-09T12:05:43Z
dc.identifier 98f1bdc4-972d-4910-89d4-a23162923d47
dc.identifier 10.2298/tsci2204845e
dc.identifier https://avesis.sdu.edu.tr/publication/details/98f1bdc4-972d-4910-89d4-a23162923d47/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/98149
dc.description In this study, a thermodynamic analysis of an industrial cabinet designed for indus-trial cabinet systems used in the food industry and providing simultaneous heating and cooling has been made. During the study, energy and exergy analyzes were carried out by using the engineering equation solver program to thermodynamic analysis of seven different refrigerants in the system designed by determining the mass-flow rate to obtain 10 kW heating power, which was selected by using the coolselector two program by using the refrigerant temperature values and operat-ing pressure values. The condenser dew point temperature was kept at +30 degrees C and the evaporator dew point temperature was kept at -1 degrees C. Calculations were made under atmospheric conditions by keeping subcooling at -2 degrees C, superheating at +5 degrees C, and ambient temperature at 20 degrees C. The coefficients determining the sys-tem performance were obtained for the highest R22 refrigerant and the lowest for R513A refrigerant. The exergy heating efficiency was obtained in the highest R22 and lowest R407C refrigerants, respectively. The calculated exergy cooling effi-ciencies were observed to be the highest R407C and the lowest R513A, respectively. The results of the study are presented in graphics. It has been revealed that the most suitable fluid in the designed industrial cabinet system is the system using R22.
dc.language eng
dc.rights info:eu-repo/semantics/openAccess
dc.title THERMODYNAMIC ANALYSIS FOR INDUSTRIAL CABINET PROVIDING SIMULTANEOUS HEATING AND COOLING THAT CAN BE USED IN THE FOOD INDUSTRY