DSpace Repository

BETONARME KİRİŞLERİN DAVRANIŞINI ETKİLEYEN PARAMETRELERİN DENEYSEL İNCELENMESİ

Show simple item record

dc.creator Demir, Fuat
dc.creator Esen, Barış
dc.creator Kabaş, Hamide
dc.creator Yaman, Sıla
dc.creator Gündoğay, Abdullah
dc.date 2022-12-01T00:00:00Z
dc.date.accessioned 2023-01-09T12:10:07Z
dc.date.available 2023-01-09T12:10:07Z
dc.identifier f90c0c9a-c70b-46ce-b736-5cd046396f14
dc.identifier 10.17482/uumfd.1120435
dc.identifier https://avesis.sdu.edu.tr/publication/details/f90c0c9a-c70b-46ce-b736-5cd046396f14/oai
dc.identifier.uri http://acikerisim.sdu.edu.tr/xmlui/handle/123456789/98556
dc.description <p>Kiriş elemanlar, döşemelerden gelen düşey yükler ile deprem, rüzgar yükü gibi yatay yüklerin kolonelemanlara aktarılmasını sağlarlar. Dolayısıyla kirişlerin kapasite değerlerine etki eden parametrelerin netolarak ortaya konulması, kolonların kapasitesinin belirlenmesi kadar önem taşımaktadır. Ülkemizdekimevcut betonarme binaların büyük çoğunluğunda beton basınç dayanımının proje dayanımından düşükolması, çekme donatısı oranının ve etriye aralığının yönetmeliklerde verilen sınır değerlere uygun olmamasıkarşılaşılan temel kusurlar arasında sayılabilir. Bu çalışmada, kiriş elemanlarda, beton dayanımı, çekmedonatısı miktarı ve etriye aralığı parametrelerinin kiriş kapasitesi üzerindeki etkisi ½ ölçekli 16 adetbetonarme kiriş numune üzerinde deneysel olarak incelenmiştir. Numuneler üç noktalı eğilme testine maruzbırakılmış ve her bir numunenin yük taşıma kapasitesi, sünekliği, enerji tüketme kapasitesi ve rijitliğihesaplanarak yorumlanmıştır. Literatürde özellikle çok düşük beton basınç dayanımına sahip kirişlerindeneysel çalışmaları oldukça az sayıdadır. Bu nedenle yapılan çalışma kapsamında üç farklı seviyede düşükbeton dayanımı dikkate alınmıştır. Elde edilen sonuçlardan beton dayanımının 5 MPa olan numunede etriyesıklaştırmasının davranış açısından çok katkısı bulunmazken, 7 ve 9 MPa beton dayanımına sahipnumunelerde hasarın daha ileri aşamalara taşınmasında katkı sağladığı görülmüştür.&nbsp;<br></p>
dc.description <p>Beam elements provide the transfer of vertical loads from the slabs and horizontal loads such asearthquake and wind loads to the column elements. Therefore, clearly revealing the parameters that affectthe capacity values of the beams is as important as determining the capacity of the columns. The maindefects encountered are the fact that the concrete compressive strength is lower than the project strength,ratio of tensile reinforcement and stirrup spacing are not in compliance with the limit values given in theregulations in the vast majority of existing reinforced concrete buildings in our country. In this study, theeffects of concrete strength, amount of tensile reinforcement and stirrup spacing parameters on beamcapacity were experimentally investigated on ½ scale 16 reinforced concrete beam specimens. Thespecimens were subjected to three-point bending test and the load carrying capacity, ductility, energydissipation capacity and stiffness of each sample were calculated and interpreted. Experimental studies ofbeams with very low concrete compressive strength are insufficient in the literature. For this reason, threedifferent levels of low concrete strength were taken into account within the scope of the study. From theresults obtained, it was seen that the stirrup densification did not contribute much to the behavior in the&nbsp;specimen with concrete strength of 5 MPa, while it contributed to the further development of the damagein specimens with concrete strength of 7 and 9 MPa.<br></p>
dc.language tur
dc.rights info:eu-repo/semantics/closedAccess
dc.title BETONARME KİRİŞLERİN DAVRANIŞINI ETKİLEYEN PARAMETRELERİN DENEYSEL İNCELENMESİ
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account