dc.description Radyoaktif olan radon gazının solunması akciğer kanseri oluşumuyla ilişkilendirilmektedir. Havalandırılması zayıf olan kapalı mekânlarda birikme eğilimi gösteren radon, zemine yakın yerlerde daha yüksek konsantrasyonlara ulaşabilmektedir. Bu çalışmada, Süleyman Demirel Üniversitesi Fizik Bölümü’nün zemin katında bulunan Isparta Radon Laboratuvarı’ndaki (IRL birimindeki) bina içi atmosferik radon konsantrasyonlarının dağılımı yüksekliğe bağlı olarak incelenmiştir. Bu amaçla IRL’de, Airthings firmasınca üretilen 3 adet Wave radon dedektörü farklı yüksekliklerdeki ölçüm noktalarına yerleştirilerek 1 Kasım 2021 ile 22 Aralık 2021 tarihleri arasında saatlik radon ölçümleri gerçekleştirilmiştir. Elde edilen ölçüm verilerine ait ortalamalar incelendiğinde, laboratuvar zeminindeki radon yoğunluğunun 303 Bq/m3, solunum seviyesindeki radon düzeyinin 220 Bq/m3 ve laboratuvarın tavan seviyesindeki radon konsantrasyonunun 212 Bq/m3 olduğu bulunmuştur. Böylelikle bina içi atmosferik radonunun yükseklik arttıkça azaldığı tespit edilmiştir. Ölçüm süreci boyunca kayıt altına alınan 3507 adet saatlik veri SPSS programıyla istatistiksel olarak analiz edilmiş, Kruskal-Wallis testine göre; alt konumdaki dedektör ölçümlerinin, orta ve üst konumdaki dedektör ölçümlerine göre istatistiksel olarak anlamlı bir farklılığa sahip olduğu (p
dc.description Exposure to radioactive radon gas through inhalation has been associated with the risk of developing lung cancer. Radon can reach high concentrations and accumulate in poorly ventilated indoor spaces near the ground. In the present study, the distribution of atmospheric radon concentrations in IRL (Isparta Radon Laboratory), located on the ground floor of the Department of Physics at Süleyman Demirel University, was examined depending on altitude. For this purpose, hourly radon measurements were carried out in IRL between 1 November 2021 and 22 December 2021 by placing 3 electronic radon detectors (Wave detectors by Airthings) at measurement points representing different heights. When the averages of the measurements were examined, it was determined that the radon concentration on the laboratory floor was 303 Bq/m3, the radon level at the respiratory level was 220 Bq/m3, and the radon concentration at the ceiling level of the laboratory was 212 Bq/m3. Thus, it was revealed that indoor atmospheric radon concentration increased with a decrease in altitude. A total of 3507 hourly data collected during the measurement process were analyzed statistically using the SPSS program. According to the Kruskal-Wallis test, it was found that the detector measurements taken in the lower position displayed a statistically significant difference (p
dc.rights info:eu-repo/semantics/closedAccess
dc.title Bina İçi Radon Birikimi Üzerine bir Araştırma
dc.type info:eu-repo/semantics/article


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account